100T3200 CNC bending machine common faults and solutions
100T3200 CNC bending machine common faults and solutions (1) : reversing valve can not reversing or reversing action is slow, generally due to poor lubrication, spring is stuck or damaged, oil or impurities stuck sliding part and other reasons. In this regard, we should first check whether the oil mist works normally; Is the viscosity of the lubricating oil appropriate? If necessary, replace the lubricating oil, clean the sliding part of the reversing valve, or replace the spring and reversing valve. Common faults and solutions of 100T3200 CNC bending machine (2) : reversing valve after a long time of use is easy to appear spool sealing ring wear, stem and seat damage phenomenon, resulting in leakage in the valve, valve action is slow or can not normal reversing and other faults. At this point, replace the sealing ring, stem and seat, or replace the reversing valve. Common faults and solutions of CNC bending machine (3) : if the inlet and exhaust holes of the electromagnetic pilot valve are blocked by debris such as mud, the sealing is not strict, the active core is stuck, the circuit has faults, etc., can lead to the normal reversing valve. In the first three cases, sludge and impurities on the pilot valve and movable iron core should be cleaned. Circuit faults are generally divided into control circuit faults and electromagnetic coil faults. Before checking… Read More »100T3200 CNC bending machine common faults and solutions